VERTISA - PROMED - MEDICAL WASTE PRE-SHREDDING UNITS

VERTISA - PROMED - MEDICAL WASTE PRE-SHREDDING UNITS

for Price / Quote
for Documentation
for Questions

FIRST SHRED - THEN STERILIZE

7 different capacity sterilization systems for specific customer needs;

 - for clinics (P50–P100–P150) and

- hospitals (P300–P500–P1000–P2000)

 

LOADING
At the beginning of the cycle, once the upper lid opens, the automatic elevator empties the waste in the loading chamber. As the upper lid closes shredding starts.

SHREDDING
The shredder, controlled by the PLC, changes rotation direction due to the “antiblocking” capability that prevents the blades to get jammed. Our special design shredders are capable of grinding very hard materials like surgical stainless steel instruments and hard ceramics. The mixing device in the upper chamber will provide the continuous feeding of the shredder.

HEATING AND STERILIZATION
Heating is achieved by injecting saturated steam until the homogeneous temperature in the upper and lower chamber reaches 134°C (274 F). Sterilization is completed by maintaining 134°C (274 F) - 138 °C (280 F) temperature and equivalent pressure for a period of 10 – 15 minutes. These factors provide the possibility to decrease the pathogenic contamination level in the medicalwasteby8 Log10value.

COOLING AND DRAININGOFCONDENSED WATER
Excess steam in the chamber is removed during cooling phase and the temperature of the grinded sterilized waste is lowered to by injecting cold air in the chamber of the autoclave. The condensed water, that sterile and can be safely discharged into the sewage system is drained with the help of positive pressure or vacuum.

UNLOADING
Once the unloading lid opens and a container is placed below the chamber, the waste trap opens to discharge the sterilized material. As the container is pulled away, the lower lid closes and the sterilizer automatically starts the next cycle.

   PROMED P 2000  PROMED P 1000 PROMED P500 PROMED P300
Size (L x W x H) (cm) 300 x 300 x 720  250 x 250 x 550 220 x 220 x 420 200 x 200 x 360
Weight (Kg) 4600 2900  2500  2200
Air Pressure (Bar max) 8 8 8 8

Electrical connection

required(Kw)

35 20 19 15

Sterilizing Capacity (Kg/ Hour)

350 –450 200 -250  150 -175 80 -100

Process Volume 

Capacity (Lt.)

2800 1400 750 400

Average Waste 

Density (Kg/m3) 

100 -150 100 -150 100 -150 100 -150

Average Cycle Time (Min.)

45 -60 35 -45  35 -45   30

Maximum Steam

Flow (Kg/Hour)

700                                        470                                        270 320                                        

Sterilization Efficiency

8 Log10 8 Log10 8 Log10 8 Log10

Steam (Kg)

40 20 15 11

Electricity (Kw) 

15 9 5 4

Water (Lt)

None None None None